65
ADVANCED FEATURES
4.40 Sweep Generator (Continued)
The START field is accessed with the METER SELECT key.
The EXIT field is accessed with the @COUNT key.
To set up a sweep from 10 MHz to 1GHz (1000 MHz) with a level of –120dBm, linear, with
100 steps, follow these keystrokes:
1. To enter the sweep function, press SHIFT,1.
2. Enter 10 MHz in the BE field.
3. Enter 1000 MHz in the FB field.
4. Set LEVEL to –120 dBm.
5. Set TYPE to linear.
6. Set the number of points to 100 in the NUM field.
7. Press METER SELECT to start the sweep, or @COUNT to exit with the changes saved so
you can start the sweep later using the SHIFT, 2 function of Sweep Start.
or
8. SHIFT, 1 will stop the sweep.
These sweep settings are saved to NVRAM memory each time you change them so the next
time you power the unit these values will be restored. They are not saved in the individual
memories.