AR2 • 22
S RE Set reset elevation statistics
Explanation: Allows resetting of all elevation statistics to zero.
Example:
S RE<CR> sent
OK<CR><LF> returned
S RP Set reset pressure statistics
Explanation: Allows resetting of all pressure statistics to zero.
Example:
S RP<CR> sent
OK<CR><LF> returned
S SR # Set sample rate index
Explanation: Allows changing of the sample rate to an index of the table val-
ues below.
Example:
S SR 4<CR> sent
OK<CR><LF> returned
One of the following
0, 1/10s<CR><LF>
1, 1/5s<CR><LF>
2, 1/2s<CR><LF>
3, 1 sec<CR><LF>
4, 5 sec<CR><LF>
5, 10sec<CR><LF>
6, 15sec<CR><LF>
7, 30sec<CR><LF>
8, 1 min<CR><LF>
9, 5 min<CR><LF>
A, 10min<CR><LF>
B, 15min<CR><LF>
S RM # Set report mode.
Explanation: Allows turning on or off automatic data reporting at each sample
rate interval. 0 = off, 1 = on.
This mode is settable only by this command. If a fast sample rate is selected
and report mode is activated you may find it nearly impossible to deactivate.
A good solution is to enter the deactivate command sequence in a text file and
then transfer it into your terminal program.
Example: